1.Application (XLPE insulated instrumentation cables):
BS5308 Cable unarmored cable are generally use for indoor installation and suitable for wet and damp areas. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, the LSOH sheath can reduce toxic smoke and fume emission.

2.Standards (XLPE insulated instrumentation cables):
IEC 60332, BS5308
3.Cable Construction (XLPE insulated instrumentation cables):
| |
Conductor | Annealed or tinned copper, sizes: 0.5mm² and 0.75mm² multi stranded(Class 5), 0.5 mm², 1.0 mm² solid(Class 1), 1.5mm² or 2.5mm², multi stranded (Class 2) to BS6360 |
Insulation | XLPE (Cross Linked Polyethylene), or PE (optional) |
Pairing | Two insulated conductors uniformly twisted together with a lay not exceeding 100mm |
Colour code | See technical information |
Binder tape | PETP transparent tape |
Collective screen | Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² |
Outer sheath | LSOH(Low Smoke Zero Halogen) sheath Flame retardant to IEC60332-3-22 Halogen free to IEC60754-1 Low smoke emission to IEC61034-1-2 |
Sheath colour | Black or blue |
4.Mechanical and Electrical Properties (XLPE insulated instrumentation cables):
Operating temperature | -20C up to + 90C( fixed installation) |
0C to +50C(during operation ) | |
Minimum bending radius | 5 x overall diameter |
Conductor Area Size | mm² | 0.5 | 0.5 | 0.75 | 1.0 | 1.5 | |
Conductor Stranding | No. x mm | 1 x 0.8 | 16 x 0.2 | 24 x 0.2 | 1 x 1.13 | 7 x 0.53 | |
Conductor resistance max | ohm/km | 36.8 | 39.7 | 26.5 | 18.2 | 12.3 | |
Insulation resistance min | Gohm/km | 5 | 5 | 5 | 5 | 5 | |
Capacitance unbalance at 1 kHz(pair to pair screen) | pF/250m | 250 | |||||
Max. Mutual Capacitance @ 1 kHz forNon OS or OS cables (except one-pair and two-pairs) | pF/m | 115 | 115 | 115 | 115 | 115 | |
Max. Mutual Capacitance @ 1 kHz IS/OS cables (include 1 pair and 2 pair) | pF/m | 75 | 75 | 75 | 75 | 75 | |
Max. L/R Ratio for adjacent cores(Inductance/ Resistance) | μH/ohm | 25 | 25 | 25 | 25 | 40 | |
Test voltage | Core to core | V | 1000 | 1000 | 1000 | 1000 | 1000 |
Core to screen | V | 1000 | 1000 | 1000 | 1000 | 1000 | |
Rated voltage max | V | 300/500 | 300/500 | 300/500 | 300/500 | 300/500 | |
5.Parameter (XLPE insulated instrumentation cables):
Number of Pairs | Number and Diameter of Wires | Nominal Conductor Cross-Sectional Area | Nominal Thickness of Insulation | Nominal Thickness of Sheath | Nominal Diameter of Cable | Approx. Weight |
no./mm | mm² | mm | mm | mm | kg/km | |
2 | 1/0.8 | 0.5 | 0.5 | 0.9 | 9.7 | 95 |
5 | 1/0.8 | 0.5 | 0.5 | 1.2 | 13 | 180 |
10 | 1/0.8 | 0.5 | 0.5 | 1.2 | 16.9 | 310 |
15 | 1/0.8 | 0.5 | 0.5 | 1.3 | 19.7 | 440 |
20 | 1/0.8 | 0.5 | 0.5 | 1.3 | 22.3 | 560 |
30 | 1/0.8 | 0.5 | 0.5 | 1.5 | 27.1 | 820 |
50 | 1/0.8 | 0.5 | 0.5 | 2 | 35 | 1370 |
2 | 16/0.2 | 0.5 | 0.6 | 1.1 | 11.2 | 110 |
5 | 16/0.2 | 0.5 | 0.6 | 1.2 | 14.5 | 250 |
10 | 16/0.2 | 0.5 | 0.6 | 1.3 | 19.3 | 480 |
15 | 16/0.2 | 0.5 | 0.6 | 1.5 | 22.6 | 570 |
20 | 16/0.2 | 0.5 | 0.6 | 1.5 | 25.7 | 780 |
30 | 16/0.2 | 0.5 | 0.6 | 1.7 | 31 | 1020 |
50 | 16/0.2 | 0.5 | 0.6 | 2.2 | 39.9 | 1680 |
2 | 1/1.13 | 1 | 0.6 | 1.1 | 11.9 | 200 |
5 | 1/1.13 | 1 | 0.6 | 1.2 | 15.4 | 290 |
10 | 1/1.13 | 1 | 0.6 | 1.3 | 20.5 | 580 |
15 | 1/1.13 | 1 | 0.6 | 1.5 | 24.1 | 780 |
20 | 1/1.13 | 1 | 0.6 | 1.7 | 27.7 | 1010 |
30 | 1/1.13 | 1 | 0.6 | 2 | 33.7 | 1430 |
50 | 1/1.13 | 1 | 0.6 | 2.2 | 42.5 | 2360 |
2 | 7/0.53 | 1.5 | 0.6 | 1.2 | 13.6 | 250 |
5 | 7/0.53 | 1.5 | 0.6 | 1.3 | 17.7 | 460 |
10 | 7/0.53 | 1.5 | 0.6 | 1.5 | 23.9 | 760 |
15 | 7/0.53 | 1.5 | 0.6 | 1.7 | 28 | 1020 |
20 | 7/0.53 | 1.5 | 0.6 | 2 | 31.7 | 1350 |
30 | 7/0.53 | 1.5 | 0.6 | 2.2 | 38.6 | 1900 |
50 | 7/0.53 | 1.5 | 0.6 | 2.2 | 48.9 | 3060 |
6.Package: Export wooden drums (XLPE insulated instrumentation cables):

Hot Tags: xlpe insulated instrumentation cables, China xlpe insulated instrumentation cables manufacturers, suppliers, factory, pvc insulated instrumentation cables, instrumentation cables, fire resistant instrument cables, , instrument cables, instrument and control cables