Instrument And Control Cables
video
Instrument And Control Cables

Instrument And Control Cables

The galvanized steel wire armor provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, the LSOH sheath can reduce toxic smoke and fume emission
Send Inquiry
Chat Now
Description

1.Application (Instrument and Control Cables):
The armoured LSOH versions (Part 1 Type 2) are generally used when the risk of mechanical damage is increased. The galvanized steel wire armor provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, the LSOH sheath can reduce toxic smoke and fume emission

1_


2.Standards (Instrument and Control Cables):
IEC 60332, BS5308


3.Instrumentation Cable Construction (Plastic insulated control cable):

Conductor : Annealed copper wires according to BS EN 60228
Insulation : Polyvinyl chloride PVC
Pairs : Twisted
Identification Pairs : Black & white, continuously numbered on white core (1, 2, 3…) for multi-element
Wrapping : 1 layer of PETP tape
Collective Screen : Aluminium / PETP tape over tinned copper drain wire
Cable Sheath : Polyvinyl Chloride PVC
Colour: Black. Blue for intrinsically safe system


4.Cable Parameters (Instrument and Control Cables):

Conductor Cross Section (Sq.mm)

Class of Conductor

No. of Strands/Max. Strand Diameter (mm)

Max. DC Conductor Resistance* at 20°C (Ω/km)

Max.L/R Ratio (μH/Ω)

Min. Insulation Resistance (GΩ x cm)

Max. Mutual Capacitance (nF/km)

Max.Inductance (mH/km)

Test Voltage Vrms (Core-Core)

Test Voltage Vrms (Core-Screen)

0.5

2

7/0.3

36

25

20

250

1

2000

2000

0.5

5

16/0.2

39

25

20

250

1

2000

2000

0.75

2

7/0.37

24.5

25

20

250

1

2000

2000

0.75

5

24/0.2

26

25

20

250

1

2000

2000

1

2

7/0.43

18.1

25

20

250

1

2000

2000

1

5

32/0.2

19.5

25

20

250

1

2000

2000

1.5

2

7/0.53

12.1

40

20

250

1

2000

2000

2.5

2

7/0.67

7.41

60

20

250

1

2000

2000



No. of Pairs and Nom.Cross Sectional Area (Sq. mm)

Min. Insulation Thickness (mm)

Nominal Sheath Thickness (mm)

Approx. Cable Diameter (mm)

Approx. Cable Weight (kg/km)

Class 5 Conductor

1 x 2 x 0.5

0.44

1

6.4

48.2

2 x 2 x 0.5

0.44

1

7.7

74.2

3 x 2 x 0.5

0.44

1.1

9

100.8

4 x 2 x 0.5

0.44

1.1

10.1

126.5

5 x 2 x 0.5

0.44

1.2

11.1

151.8

8 x 2 x 0.5

0.44

1.3

13.6

225.5

10 x 2 x 0.5

0.44

1.3

15

274

12 x 2 x 0.5

0.44

1.4

16.2

321.9

16 x 2 x 0.5

0.44

1.4

18.4

416.1

20 x 2 x 0.5

0.44

1.5

20.4

510

24 x 2 x 0.5

0.44

1.6

22.2

603.1

1 x 2 x 0.75

0.44

1

6.8

56.7

2 x 2 x 0.75

0.44

1.1

8.3

89.5

3 x 2 x 0.75

0.44

1.1

9.7

122.9

4 x 2 x 0.75

0.44

1.2

10.9

155.8

5 x 2 x 0.75

0.44

1.2

12

188

8 x 2 x 0.75

0.44

1.3

14.7

282.2

10 x 2 x 0.75

0.44

1.4

16.2

345

12 x 2 x 0.75

0.44

1.4

17.6

406.3

16 x 2 x 0.75

0.44

1.5

20

527.7

20 x 2 x 0.75

0.44

1.6

22.2

649.5

24 x 2 x 0.75

0.44

1.6

24.1

769

1 x 2 x 1

0.44

1

7.1

64.1

2 x 2 x 1

0.44

1.1

8.7

103.4

3 x 2 x 1

0.44

1.1

10.2

143.1

4 x 2 x 1

0.44

1.2

11.5

182.2

5 x 2 x 1

0.44

1.2

12.6

220.5

8 x 2 x 1

0.44

1.3

15.5

333.8

10 x 2 x 1

0.44

1.4

17.1

408.9

12 x 2 x 1

0.44

1.4

18.6

482.3

16 x 2 x 1

0.44

1.5

21.2

629

20 x 2 x 1

0.44

1.6

23.5

776.5

24 x 2 x 1

0.44

1.7

25.5

920.3

Class 2 Conductor

1 x 2 x 0.5

0.44

1

6.4

48

2 x 2 x 0.5

0.44

1

7.7

73.9

3 x 2 x 0.5

0.44

1.1

9

100.4

4 x 2 x 0.5

0.44

1.1

10.1

125.9

5 x 2 x 0.5

0.44

1.2

11.1

151.2

8 x 2 x 0.5

0.44

1.3

13.6

224.5

10 x 2 x 0.5

0.44

1.3

15

272.7

12 x 2 x 0.5

0.44

1.4

16.2

320.4

16 x 2 x 0.5

0.44

1.4

18.4

414.1

20 x 2 x 0.5

0.44

1.5

20.4

507.5

24 x 2 x 0.5

0.44

1.6

22.2

600.1

1 x 2 x 0.75

0.44

1

6.8

56.7

2 x 2 x 0.75

0.44

1.1

8.3

89.5

3 x 2 x 0.75

0.44

1.1

9.7

123.4

4 x 2 x 0.75

0.44

1.2

10.9

155.9

5 x 2 x 0.75

0.44

1.2

12

188

8 x 2 x 0.75

0.44

1.3

14.7

282.4

10 x 2 x 0.75

0.44

1.4

16.3

345.1

12 x 2 x 0.75

0.44

1.4

17.6

406.4

16 x 2 x 0.75

0.44

1.5

20.1

527.9

20 x 2 x 0.75

0.44

1.6

22.2

649.7

24 x 2 x 0.75

0.44

1.6

24.2

769.4

1 x 2 x 1

0.44

1

7.2

65.2

2 x 2 x 1

0.44

1.1

8.8

105.6

3 x 2 x 1

0.44

1.1

10.4

146.7

4 x 2 x 1

0.44

1.2

11.7

186.8

5 x 2 x 1

0.44

1.2

12.9

226.1

8 x 2 x 1

0.44

1.3

15.8

342.3

10 x 2 x 1

0.44

1.4

17.4

419.3

12 x 2 x 1

0.44

1.5

19

495.5

16 x 2 x 1

0.44

1.6

21.6

646

20 x 2 x 1

0.44

1.6

23.9

796.2

24 x 2 x 1

0.44

1.7

26

945

1 x 2 x 1.5

0.44

1

7.9

81.9

2 x 2 x 1.5

0.44

1.1

9.7

136.4

3 x 2 x 1.5

0.44

1.2

11.5

191.5

4 x 2 x 1.5

0.44

1.2

13

246

5 x 2 x 1.5

0.44

1.3

14.3

299.7

8 x 2 x 1.5

0.44

1.4

17.7

457.6

10 x 2 x 1.5

0.44

1.5

19.5

563.2

12 x 2 x 1.5

0.44

1.5

21.2

666.6

16 x 2 x 1.5

0.44

1.6

24.2

872.3

20 x 2 x 1.5

0.44

1.7

26.8

1079.7

24 x 2 x 1.5

0.44

1.8

29.2

1283.9

1 x 2 x 2.5

0.53

1.1

9.3

113.8

2 x 2 x 2.5

0.53

1.2

11.5

195.3

3 x 2 x 2.5

0.53

1.3

13.6

278.3

4 x 2 x 2.5

0.53

1.3

15.5

360.2

5 x 2 x 2.5

0.53

1.4

17.1

441.1

8 x 2 x 2.5

0.53

1.5

21.1

680.6

10 x 2 x 2.5

0.53

1.6

23.4

840.3

12 x 2 x 2.5

0.53

1.7

25.5

998.3

16 x 2 x 2.5

0.53

1.8

29.1

1310.9

20 x 2 x 2.5

0.53

1.9

32.3

1627.1

24 x 2 x 2.5

0.53

2.1

35.2

1938.7


5.Package: Export wooden drums (Instrument and Control Cables):

1


Hot Tags: instrument and control cables, China instrument and control cables manufacturers, suppliers, factory, fire resistant instrument cables, , instrumentation cables, instrument cables, pvc insulated instrumentation cables, instrument and control cables

Send Inquiry

(0/10)

clearall