Flame Retardant Instrument Cables
video
Flame Retardant Instrument Cables

Flame Retardant Instrument Cables

BS 5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemicals industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity and microphone.
Send Inquiry
Chat Now
Description

1.Application (Flame Retardant Instrument Cables):
BS 5308 cables are designed to carry communication and control signals in a variety of installation types including those found in the petrochemicals industry. The signals can be of analogue, data or voice type and from a variety of transducers such as pressure, proximity and microphone. Part 1 Type 3 cables are generally designed where a greater degree of mechanical and chemical protection is required or direct burial at a suitable depth. Collectively and individually screened pairs are available within the range. For installations where fire, smoke emission and toxic fumes create a potential risk to life and equipment.

3


2.Standards (Flame Retardant Instrument Cables):
IEC 60332, BS5308


3.Cable Construction (Flame Retardant Instrument Cables):

Conductor
Class 1 solid copper conductor according to BS EN 60228
Class 2 stranded copper conductor according to BS EN 60228 Class 5 flexible copper conductor according to BS EN 60228
Insulation
XLPE Type 03
Binder Tape
PET (Polyester Tape)
Screen
AL/PET (Aluminium/Polyester Tape)
Drain Wire
Tinned copper
Bedding
LSZH (Low Smoke Zero Halogen) Type LTS3 acc. to BS 7655
Covering
Lead or polyamide cover
Inner Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 acc. to BS 7655
Armour
Galvanized steel wires
Outer Sheath
LSZH (Low Smoke Zero Halogen) Type LTS3 acc. to BS 7655


4.Cable Parameters (Flame Retardant Instrument Cables):

Conductor Cross Section (Sq.mm)

Class of Conductor

No. of Strands/Max. Strand Diameter (mm)

Max. DC Conductor Resistance* at 20°C (Ω/km)

Max.L/R Ratio (μH/Ω)

Min. Insulation Resistance (GΩ x cm)

Max. Mutual Capacitance (nF/km)

Max.Inductance (mH/km)

Test Voltage Vrms (Core-Core)

Test Voltage Vrms (Core-Screen)

0.5

2

7/0.3

36

25

20

250

1

2000

2000

0.5

5

16/0.2

39

25

20

250

1

2000

2000

0.75

2

7/0.37

24.5

25

20

250

1

2000

2000

0.75

5

24/0.2

26

25

20

250

1

2000

2000

1

2

7/0.43

18.1

25

20

250

1

2000

2000

1

5

32/0.2

19.5

25

20

250

1

2000

2000

1.5

2

7/0.53

12.1

40

20

250

1

2000

2000

2.5

2

7/0.67

7.41

60

20

250

1

2000

2000



No. of Pairs and Nom.Cross Sectional Area (Sq. mm)

Min. Insulation Thickness (mm)

Nominal Sheath Thickness (mm)

Approx. Cable Diameter (mm)

Approx. Cable Weight (kg/km)

Class 5 Conductor

1 x 2 x 0.5

0.44

1

6.4

48.2

2 x 2 x 0.5

0.44

1

7.7

74.2

3 x 2 x 0.5

0.44

1.1

9

100.8

4 x 2 x 0.5

0.44

1.1

10.1

126.5

5 x 2 x 0.5

0.44

1.2

11.1

151.8

8 x 2 x 0.5

0.44

1.3

13.6

225.5

10 x 2 x 0.5

0.44

1.3

15

274

12 x 2 x 0.5

0.44

1.4

16.2

321.9

16 x 2 x 0.5

0.44

1.4

18.4

416.1

20 x 2 x 0.5

0.44

1.5

20.4

510

24 x 2 x 0.5

0.44

1.6

22.2

603.1

1 x 2 x 0.75

0.44

1

6.8

56.7

2 x 2 x 0.75

0.44

1.1

8.3

89.5

3 x 2 x 0.75

0.44

1.1

9.7

122.9

4 x 2 x 0.75

0.44

1.2

10.9

155.8

5 x 2 x 0.75

0.44

1.2

12

188

8 x 2 x 0.75

0.44

1.3

14.7

282.2

10 x 2 x 0.75

0.44

1.4

16.2

345

12 x 2 x 0.75

0.44

1.4

17.6

406.3

16 x 2 x 0.75

0.44

1.5

20

527.7

20 x 2 x 0.75

0.44

1.6

22.2

649.5

24 x 2 x 0.75

0.44

1.6

24.1

769

1 x 2 x 1

0.44

1

7.1

64.1

2 x 2 x 1

0.44

1.1

8.7

103.4

3 x 2 x 1

0.44

1.1

10.2

143.1


4 x 2 x 1

0.44

1.2

11.5

182.2

5 x 2 x 1

0.44

1.2

12.6

220.5

8 x 2 x 1

0.44

1.3

15.5

333.8

10 x 2 x 1

0.44

1.4

17.1

408.9

12 x 2 x 1

0.44

1.4

18.6

482.3

16 x 2 x 1

0.44

1.5

21.2

629

20 x 2 x 1

0.44

1.6

23.5

776.5

24 x 2 x 1

0.44

1.7

25.5

920.3

Class 2 Conductor

1 x 2 x 0.5

0.44

1

6.4

48

2 x 2 x 0.5

0.44

1

7.7

73.9

3 x 2 x 0.5

0.44

1.1

9

100.4

4 x 2 x 0.5

0.44

1.1

10.1

125.9

5 x 2 x 0.5

0.44

1.2

11.1

151.2

8 x 2 x 0.5

0.44

1.3

13.6

224.5

10 x 2 x 0.5

0.44

1.3

15

272.7

12 x 2 x 0.5

0.44

1.4

16.2

320.4

16 x 2 x 0.5

0.44

1.4

18.4

414.1

20 x 2 x 0.5

0.44

1.5

20.4

507.5

24 x 2 x 0.5

0.44

1.6

22.2

600.1

1 x 2 x 0.75

0.44

1

6.8

56.7

2 x 2 x 0.75

0.44

1.1

8.3

89.5

3 x 2 x 0.75

0.44

1.1

9.7

123.4

4 x 2 x 0.75

0.44

1.2

10.9

155.9

5 x 2 x 0.75

0.44

1.2

12

188

8 x 2 x 0.75

0.44

1.3

14.7

282.4

10 x 2 x 0.75

0.44

1.4

16.3

345.1

12 x 2 x 0.75

0.44

1.4

17.6

406.4

16 x 2 x 0.75

0.44

1.5

20.1

527.9

20 x 2 x 0.75

0.44

1.6

22.2

649.7

24 x 2 x 0.75

0.44

1.6

24.2

769.4

1 x 2 x 1

0.44

1

7.2

65.2

2 x 2 x 1

0.44

1.1

8.8

105.6

3 x 2 x 1

0.44

1.1

10.4

146.7

4 x 2 x 1

0.44

1.2

11.7

186.8

5 x 2 x 1

0.44

1.2

12.9

226.1

8 x 2 x 1

0.44

1.3

15.8

342.3

10 x 2 x 1

0.44

1.4

17.4

419.3

12 x 2 x 1

0.44

1.5

19

495.5

16 x 2 x 1

0.44

1.6

21.6

646

20 x 2 x 1

0.44

1.6

23.9

796.2

24 x 2 x 1

0.44

1.7

26

945

1 x 2 x 1.5

0.44

1

7.9

81.9

2 x 2 x 1.5

0.44

1.1

9.7

136.4

3 x 2 x 1.5

0.44

1.2

11.5

191.5

4 x 2 x 1.5

0.44

1.2

13

246

5 x 2 x 1.5

0.44

1.3

14.3

299.7

8 x 2 x 1.5

0.44

1.4

17.7

457.6

10 x 2 x 1.5

0.44

1.5

19.5

563.2

12 x 2 x 1.5

0.44

1.5

21.2

666.6

16 x 2 x 1.5

0.44

1.6

24.2

872.3

20 x 2 x 1.5

0.44

1.7

26.8

1079.7

24 x 2 x 1.5

0.44

1.8

29.2

1283.9

1 x 2 x 2.5

0.53

1.1

9.3

113.8

2 x 2 x 2.5

0.53

1.2

11.5

195.3

3 x 2 x 2.5

0.53

1.3

13.6

278.3

4 x 2 x 2.5

0.53

1.3

15.5

360.2

5 x 2 x 2.5

0.53

1.4

17.1

441.1

8 x 2 x 2.5

0.53

1.5

21.1

680.6

10 x 2 x 2.5

0.53

1.6

23.4

840.3

12 x 2 x 2.5

0.53

1.7

25.5

998.3

16 x 2 x 2.5

0.53

1.8

29.1

1310.9

20 x 2 x 2.5

0.53

1.9

32.3

1627.1

24 x 2 x 2.5

0.53

2.1

35.2

1938.7


5.Package: Export wooden drums (Fire Resistant Instrument Cables):

1


Hot Tags: flame retardant instrument cables, China flame retardant instrument cables manufacturers, suppliers, factory, instrument cables, instrument and control cables, instrumentation cables, fire resistant instrument cables, , pvc insulated instrumentation cables

Send Inquiry

(0/10)

clearall