1.Application (Plastic insulated control cable):
Wiring for controlling electrical equipment and instrument meters, monitoring and controlling return circuit, protecting and measuring in power distribution with rated voltage up to 450/750V(0.6/1KV) A.C.

2.Standards(Plastic insulated control cable):
GB/T9330-2008 ,IEC 60502, etc
3.Type, descriptions and applications(Plastic insulated control cable):
Chinese Type | Descriptions | Applications |
KVV | Copper conductor PVC insulated PVC sheathed control cables | For laying indoor, in tunnels, ducts, |
KVVR | Copper conductor PVC insulated and sheathed flexible control cable | For laying indoor ,in tunnels, ducts and movable using |
KVVP | Copper conductor PVC insulated and sheathed copper wire braiding shielded control cable | For laying indoor, in tunnels, ducts, conduit etc. Permanent place where shield required. |
KVVRP | Copper conductor PVC insulated and sheathed copper wire braiding shielded flexible control cable | For laying indoor ,in tunnels, ducts and flexible and shield required etc.place, easy to move |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape shielded control cables | For laying indoor, in tunnels, ducts, conduit etc. Permanent place where shield required. |
KVVP2-22 | Copper conductor PVC Insulated PVC Sheathed Copper Tape shielded steel tape armored Control Cables | Used in light-current control system and heavy-current magnetic interference region. |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cables | For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cables | For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force |
4.Cable Parameters(Plastic insulated control cable):
KVV type, 450/750V(0.6/1kV)Copper Conductor PVC Insulated and Sheathed Control Cable to GB/T9330-2008
Number of cores×Nominal cross section | Nominal thickness of insulation | Nominal sheath thickness | Average overall diameter | Max.DC resistance of conductor at 20 ℃ | Approx. Weight of cable | |
Limit | Caps | |||||
2×0.75 | 0.6 | 1.2 | 6.7 | 8.1 | 24.5 | 62.8 |
3×0.75 | 0.6 | 1.2 | 7.1 | 8.5 | 24.5 | 78.3 |
4×0.75 | 0.6 | 1.2 | 7.6 | 9.2 | 24.5 | 93.2 |
5×0.75 | 0.6 | 1.2 | 8.2 | 9.9 | 24.5 | 106.3 |
7×0.75 | 0.6 | 1.2 | 8.8 | 10.6 | 24.5 | 129.2 |
8×0.75 | 0.6 | 1.2 | 9.7 | 11.7 | 24.5 | 144.6 |
10×0.75 | 0.6 | 1.5 | 10.8 | 13.1 | 24.5 | 193.4 |
5.Package: Export wooden drums (Plastic insulated control cable):

Hot Tags: plastic insulated control cable, China plastic insulated control cable manufacturers, suppliers, factory, braided control cables, pvc insulated control cable