Low Smoke Zero Halogen Cable
video
Low Smoke Zero Halogen Cable

Low Smoke Zero Halogen Cable

1)Low smoke zero halogen cable,CU/LSZH/LSZH, 0.6/1 kV, IEC 60502-1
2)Application: Power Station, Building, Engineered, Railway, Plant construction, School, Hospital, Underground and so on.
Send Inquiry
Chat Now
Description

Low smoke zero halogen cable,CU/LSZH/LSZH,0.6/1 kV, IEC 60502-1.
Application (Low smoke zero halogen cable):
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction (Low smoke zero halogen cable):
Conductors
Solid copper conductor Class 1, Stranded Copper conductor Class 2 to IEC 60228, BS EN 60228.
Insulation
LSZH material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.

Colour Code
Colour Code (1) :
1 Core: Transparent, Red or Black
2 Cores: Red, Black
3 Cores: Red, Yellow, Blue
4 Cores: Red, Yellow, Blue, Black
5 Cores: Red, Yellow, Blue, Black, Green
Above 5 Cores: Black Cores with White numerals
Colour Code (2) :
1 Core: Transparent,Brown or Blue
2 Cores: Brown or Blue
3 Cores: Brown, Black, Grey
4 Cores: Blue, Brown, Black, Grey
5 Cores: Green/Yellow, Blue, Brown, Black, Grey
Above 5 Cores: Black Cores with White numerals

Outer Sheath
Outer sheath shall be of Extruded LSZH as per IEC 60502-1 or Type 9 as BS 6346/5467.


Cable Parameters(Low smoke zero halogen cable):

1

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

1x1.5

1.4

0.7

1.4

5.6

1x2.5

1.8

0.7

1.4

6.0

1x4

2.3

0.7

1.4

6.5

1x6

2.8

0.7

1.4

7.0

1x10

3.6

0.7

1.4

7.8

1x16

4.5

0.7

1.4

8.7

1x25

5.6

0.9

1.4

10.2

1x35

6.7

0.9

1.4

11.3

1x50

8.0

1

1.4

12.8

1x70

9.4

1.1

1.4

14.4

1x95

11.0

1.1

1.5

16.1

1x120

12.4

1.2

1.5

17.8

1x150

13.8

1.4

1.6

19.8

1x185

15.3

1.6

1.6

21.8

1x240

17.5

1.7

1.7

24.4

1x300

19.5

1.8

1.8

26.7

1x400

22.6

2

1.9

30.5

1x500

25.2

2.2

2.0

33.7

1x630

28.3

2.4

2.2

37.4

1x800

31.9

2.6

2.3

41.7

1x1000

35.7

2.8

2.4

46.2


2

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

2x1.5

1.4

0.7

1.8

9.2

2x2.5

1.8

0.7

1.8

10.0

2x4

2.3

0.7

1.8

11.0

2x6

2.8

0.7

1.8

12.0

2x10

3.6

0.7

1.8

13.6

2x16

4.5

0.7

1.8

15.4

2x25

5.6

0.9

1.8

18.4

2x35

6.7

0.9

1.8

20.6

2x50

8.0

1

1.8

23.6

2x70

9.4

1.1

1.8

26.8

2x95

11.0

1.1

1.9

30.2

2x120

12.4

1.2

2.0

33.7

2x150

13.8

1.4

2.2

37.5

2x185

15.3

1.6

2.3

41.6

2x240

17.5

1.7

2.5

46.7

2x300

19.5

1.8

2.6

51.4

2x400

22.6

2

2.9

58.9


3

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

3x1.5

1.4

0.7

1.8

9.6

3x2.5

1.8

0.7

1.8

10.5

3x4

2.3

0.7

1.8

11.6

3x6

2.8

0.7

1.8

12.6

3x10

3.6

0.7

1.8

14.4

3x16

4.5

0.7

1.8

16.3

3x25

5.6

0.9

1.8

19.5

3x35

6.7

0.9

1.8

21.9

3x50

8.0

1

1.8

25.1

3x70

9.4

1.1

1.9

28.7

3x95

11.0

1.1

2.0

32.4

3x120

12.4

1.2

2.1

36.1

3x150

13.8

1.4

2.3

40.3

3x185

15.3

1.6

2.4

44.6

3x240

17.5

1.7

2.6

50.2

3x300

19.5

1.8

2.7

55.2

3x400

22.6

2

3.0

63.3


4

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

4x1.5

1.4

0.7

1.8

10.4

4x2.5

1.8

0.7

1.8

11.3

4x4

2.3

0.7

1.8

12.5

4x6

2.8

0.7

1.8

13.7

4x10

3.6

0.7

1.8

15.7

4x16

4.5

0.7

1.8

17.8

4x25

5.6

0.9

1.8

21.5

4x35

6.7

0.9

1.8

24.1

4x50

8.0

1

1.8

27.8

4x70

9.4

1.1

2.0

32.0

4x95

11.0

1.1

2.1

36.1

4x120

12.4

1.2

2.3

40.2

4x150

13.8

1.4

2.4

44.9

4x185

15.3

1.6

2.6

49.8

4x240

17.5

1.7

2.8

56.0

4x300

19.5

1.8

3.0

61.7

4x400

22.6

2

3.2

70.7


5

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

5x1.5

1.4

0.7

1.8

11.2

7x1.5

1.4

0.7

1.8

12.0

10x1.5

1.4

0.7

1.8

14.8

12x1.5

1.4

0.7

1.8

15.2

14x1.5

1.4

0.7

1.8

16.0

19x1.5

1.4

0.7

1.8

17.6

21x1.5

1.4

0.7

1.8

18.4

24x1.5

1.4

0.7

1.8

20.4

30x1.5

1.4

0.7

1.8

21.6

40x1.5

1.4

0.7

1.8

26.0

48x1.5

1.4

0.7

1.8

26.4

61x1.5

1.4

0.7

1.9

29.0

5x2.5

1.8

0.7

1.8

12.2

7x2.5

1.8

0.7

1.8

13.2

10x2.5

1.8

0.7

1.8

16.4

12x2.5

1.8

0.7

1.8

16.9

14x2.5

1.8

0.7

1.8

17.7

19x2.5

1.8

0.7

1.8

19.6

21x2.5

1.8

0.7

1.8

20.6

24x2.5

1.8

0.7

1.8

22.8

30x2.5

1.8

0.7

1.8

24.1

40x2.5

1.8

0.7

1.9

29.4

48x2.5

1.8

0.7

1.9

29.9

61x2.5

1.8

0.7

2.0

32.8


Package: Export wooden drums.