Aluminum Conductor XLPE Insulated Wire ABC Cable
video
Aluminum Conductor XLPE Insulated Wire ABC Cable

Aluminum Conductor XLPE Insulated Wire ABC Cable

Aluminum Conductor XLPE Insulated wire ABC Cable
ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard
Send Inquiry
Chat Now
Description

Aluminum Conductor XLPE Insulated wire ABC Cable

 

We produce the ABC Electric Cable used for overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM, BS, NF C 33-209 standard.

ABC cable 14 ABC cable 1 ABC cable 44


Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

Detailed Introduction of Service Drop Cable
1 Duplex Service Drop
Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction: Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

2 Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction: Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3 Quadruplex Service Drop
Applications: Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction: Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

 

Specification:

Phase

Phase

Phase

Approx. Overall Diameter

Max. D. C.

Resistance of Conductor

at 20℃

AAC+UV-XLPE

Compact Conductor

UV-XLPE Insulation

No. *  Cross Section of Cores

No. of

Al Wires

Overall Diameter

Normal

Thickness

Min.

Thickness

Diameter

No. X mm 2

-

mm

mm

mm

mm

mm

Ohm/km

1 X 10

7

4.05

1.0

0.8

6.05

6.05

3.08

1 X 16

7

4.8

1.2

0.98

7.2

7.20

1.91

1 X 25

7

6

1.2

0.98

8.4

8.40

1.20

1 X 35

7

7.0

1.4

1.16

9.8

9.80

0.868

1 X 50

7

8.3

1.4

1.16

11.1

11.10

0.641

1 X 70

19

9.8

1.4

1.16

12.6

12.60

0.443

1 X 95

19

11.6

1.6

1.34

14.8

14.80

0.320

1 X 120

19

13

1.6

1.34

16.2

16.20

0.253

1 X 150

19

14.6

1.8

1.52

18.2

18.20

0.206

1 X 185

36

16.2

2.0

1.70

20.2

20.20

0.164

1 X 240

36

18.4

2.2

1.88

22.8

22.80

0.125

2 X 10

7

4.05

1.0

0.8

6.05

12.10

3.08

2 X 16

7

4.8

1.2

0.98

7.2

14.40

1.91

2 X 25

7

6

1.2

0.98

8.4

16.80

1.20

2 X 35

7

7.0

1.4

1.16

9.8

19.60

0.868

2 X 50

7

8.3

1.4

1.16

11.1

22.20

0.641

2 X 70

19

9.8

1.4

1.16

12.6

25.20

0.443

2 X 95

19

11.6

1.6

1.34

14.8

29.60

0.320

2 X 120

19

13

1.6

1.34

16.2

32.40

0.253

2 X 150

19

14.6

1.8

1.52

18.2

36.40

0.206

2 X 185

36

16.2

2.0

1.70

20.2

40.40

0.164

2 X 240

36

18.4

2.2

1.88

22.8

45.60

0.125

3 X 10

7

4.05

1.0

0.8

6.05

13.07

3.08

3 X 16

7

4.8

1.2

0.98

7.2

15.55

1.91

3 X 25

7

6

1.2

0.98

8.4

18.14

1.20

3 X 35

7

7.0

1.4

1.16

9.8

21.17

0.868

3 X 50

7

8.3

1.4

1.16

11.1

23.98

0.641

3 X 70

19

9.8

1.4

1.16

12.6

27.22

0.443

3 X 95

19

11.6

1.6

1.34

14.8

31.97

0.320

3 X 120

19

13

1.6

1.34

16.2

34.99

0.253

3 X 150

19

14.6

1.8

1.52

18.2

39.31

0.206

3 X 185

36

16.2

2.0

1.70

20.2

43.63

0.164

3 X 240

36

18.4

2.2

1.88

22.8

49.25

0.125

4 X 10

7

4.05

1.0

0.8

6.05

14.64

3.08

4 X 16

7

4.8

1.2

0.98

7.2

17.42

1.91

4 X 25

7

6

1.2

0.98

8.4

20.33

1.20

4 X 35

7

7.0

1.4

1.16

9.8

23.72

0.868

4 X 50

7

8.3

1.4

1.16

11.1

26.86

0.641

4 X 70

19

9.8

1.4

1.16

12.6

30.49

0.443

4 X 95

19

11.6

1.6

1.34

14.8

35.82

0.320

4 X 120

19

13

1.6

1.34

16.2

39.20

0.253

4 X 150

19

14.6

1.8

1.52

18.2

44.04

0.206

4 X 185

36

16.2

2.0

1.70

20.2

48.88

0.164

4 X 240

36

18.4

2.2

1.88

22.8

55.18

0.125

 

Package: Export wooden drums ,overhead abc cable

ABC CABLE ABC CABLE 02 ABC CABLE 03

 

Hot Tags: aluminum conductor xlpe insulated wire abc cable, China aluminum conductor xlpe insulated wire abc cable manufacturers, suppliers, factory, abc cable, , aerial bundle cables, aerial bundled cables

Send Inquiry

(0/10)

clearall