XLPE Insulated Cable
video
XLPE Insulated Cable

XLPE Insulated Cable

-CU/XLPE/PVC, XLPE Insulated Cable, Rated Voltage:0.6/1KV.
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants.
-According to IEC 60502-1,GB12706.
-Flame Retardant Cable & LSZH Cable& PVC Cable
-Large stock cables with different sizes
Send Inquiry
Chat Now
Description

Application (XLPE Insulated Cable):
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.


Construction(XLPE Insulated Cable):

Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.


Insulation

XLPE Insulation material and thickness shall be as per IEC 60502-1, rated for 90°C continuous operation.


Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.


Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

1_

2_

3_

4_


Cable Parameters(XLPE Insulated Cable):

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

1x1.5

1.4

0.7

1.4

5.6

1x2.5

1.8

0.7

1.4

6

1x4

2.3

0.7

1.4

6.5

1x6

2.8

0.7

1.4

7

1x10

3.6

0.7

1.4

7.8

1x16

4.5

0.7

1.4

8.7

1x25

5.6

0.9

1.4

10.2

1x35

6.7

0.9

1.4

11.3

1x50

8

1

1.4

12.8

1x70

9.4

1.1

1.4

14.4

1x95

11

1.1

1.5

16.1

1x120

12.4

1.2

1.5

17.8

1x150

13.8

1.4

1.6

19.8

1x185

15.3

1.6

1.6

21.8

1x240

17.5

1.7

1.7

24.4

1x300

19.5

1.8

1.8

26.7

1x400

22.6

2

1.9

30.5

1x500

25.2

2.2

2

33.7

1x630

28.3

2.4

2.2

37.4

1x800

31.9

2.6

2.3

41.7

1x1000

35.7

2.8

2.4

46.2


Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

2x1.5

1.4

0.7

1.8

9.2

2x2.5

1.8

0.7

1.8

10

2x4

2.3

0.7

1.8

11

2x6

2.8

0.7

1.8

12

2x10

3.6

0.7

1.8

13.6

2x16

4.5

0.7

1.8

15.4

2x25

5.6

0.9

1.8

18.4

2x35

6.7

0.9

1.8

20.6

2x50

8

1

1.8

23.6

2x70

9.4

1.1

1.8

26.8

2x95

11

1.1

1.9

30.2

2x120

12.4

1.2

2

33.7

2x150

13.8

1.4

2.2

37.5

2x185

15.3

1.6

2.3

41.6

2x240

17.5

1.7

2.5

46.7

2x300

19.5

1.8

2.6

51.4

2x400

22.6

2

2.9

58.9



Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

3x1.5

1.4

0.7

1.8

9.6

3x2.5

1.8

0.7

1.8

10.5

3x4

2.3

0.7

1.8

11.6

3x6

2.8

0.7

1.8

12.6

3x10

3.6

0.7

1.8

14.4

3x16

4.5

0.7

1.8

16.3

3x25

5.6

0.9

1.8

19.5

3x35

6.7

0.9

1.8

21.9

3x50

8

1

1.8

25.1

3x70

9.4

1.1

1.9

28.7

3x95

11

1.1

2

32.4

3x120

12.4

1.2

2.1

36.1

3x150

13.8

1.4

2.3

40.3

3x185

15.3

1.6

2.4

44.6

3x240

17.5

1.7

2.6

50.2

3x300

19.5

1.8

2.7

55.2

3x400

22.6

2

3

63.3




Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

(3)mm

(1)mm

(3)mm

(1)mm

mm

mm

3x 16/10

4.5

3.6

0.7

0.7

1.8

17.5

3x 25/16

5.6

4.5

0.9

0.7

1.8

21.2

3x 35/16

6.7

4.5

0.9

0.7

1.8

23.8

3x 50/25

8

5.6

1

0.9

1.8

27.5

3x 70/35

9.4

6.7

1.1

0.9

2

31.7

3x 95/50

11

8

1.1

1

2.1

35.8

3x120/70

12.4

9.4

1.2

1.1

2.3

39.9

3x150/70

13.8

9.4

1.4

1.1

2.4

44.6

3x185/95

15.3

11

1.6

1.1

2.6

49.5

3x240/120

17.5

12.4

1.7

1.2

2.8

55.7

3x300/150

19.5

13.8

1.8

1.4

3

61.4

3x400/185

22.6

15.3

2

1.6

3.2

70.4



Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

4x1.5

1.4

0.7

1.8

10.4

4x2.5

1.8

0.7

1.8

11.3

4x4

2.3

0.7

1.8

12.5

4x6

2.8

0.7

1.8

13.7

4x10

3.6

0.7

1.8

15.7

4x16

4.5

0.7

1.8

17.8

4x25

5.6

0.9

1.8

21.5

4x35

6.7

0.9

1.8

24.1

4x50

8

1

1.8

27.8

4x70

9.4

1.1

2

32

4x95

11

1.1

2.1

36.1

4x120

12.4

1.2

2.3

40.2

4x150

13.8

1.4

2.4

44.9

4x185

15.3

1.6

2.6

49.8

4x240

17.5

1.7

2.8

56

4x300

19.5

1.8

3

61.7

4x400

22.6

2

3.2

70.7


Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

5x1.5

1.4

0.7

1.8

11.2

7x1.5

1.4

0.7

1.8

12

10x1.5

1.4

0.7

1.8

14.8

12x1.5

1.4

0.7

1.8

15.2

14x1.5

1.4

0.7

1.8

16

19x1.5

1.4

0.7

1.8

17.6

21x1.5

1.4

0.7

1.8

18.4

24x1.5

1.4

0.7

1.8

20.4

30x1.5

1.4

0.7

1.8

21.6

40x1.5

1.4

0.7

1.8

26

48x1.5

1.4

0.7

1.8

26.4

61x1.5

1.4

0.7

1.9

29

5x2.5

1.8

0.7

1.8

12.2

7x2.5

1.8

0.7

1.8

13.2

10x2.5

1.8

0.7

1.8

16.4

12x2.5

1.8

0.7

1.8

16.9

14x2.5

1.8

0.7

1.8

17.7

19x2.5

1.8

0.7

1.8

19.6

21x2.5

1.8

0.7

1.8

20.6

24x2.5

1.8

0.7

1.8

22.8

30x2.5

1.8

0.7

1.8

24.1

40x2.5

1.8

0.7

1.9

29.4

48x2.5

1.8

0.7

1.9

29.9

61x2.5

1.8

0.7

2

32.8


Package Material:
Wooden drum, Steel wooden drum (fumigation)