Underground Cables, Armored Cable
1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
![]() |
![]() |
2.Construction
- Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
- Insulation
XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90C continuous operation.
- Colour Code
|
Colour Code (1) |
Colour Code (2) |
||
|
1 Core |
Red or Black |
1 Core |
Brown or Blue |
|
2 Cores |
Red, Black |
2 Cores |
Brown, Blue |
|
3 Cores |
Red, Yellow, Blue |
3 Cores |
Brown, Black, Grey |
|
4 Cores |
Red, Yellow, Blue, Black |
4 Cores |
Blue, Brown, Black, Grey |
|
5 Cores |
Red, Yellow, Blue, Black, Green |
5 Cores |
Green/Yellow, Blue, Brown, Black, Grey |
|
Above 5 Cores |
Black Cores with White numerals |
Above 5 Cores |
Black Cores with White numerals |
Other colors can be manufactured upon request.
-Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
-Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
-Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
-Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Cable Parameters
-Single core armored cable
|
Single core ( aluminum wire armoured) |
|
||||||
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
|
|
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
|
|
1x4 |
2.3 |
0.7 |
1.0 |
0.8 |
1.8 |
10.9 |
|
|
1x6 |
2.8 |
0.7 |
1.0 |
0.8 |
1.8 |
11.4 |
|
|
1x10 |
3.6 |
0.7 |
1.0 |
0.8 |
1.8 |
12.2 |
|
|
1x16 |
4.5 |
0.7 |
1.0 |
0.8 |
1.8 |
13.1 |
|
|
1x25 |
5.6 |
0.9 |
1.0 |
0.8 |
1.8 |
14.6 |
|
|
1x35 |
6.7 |
0.9 |
1.0 |
1.25 |
1.8 |
16.6 |
|
|
1x50 |
8.0 |
1 |
1.0 |
1.25 |
1.8 |
18.1 |
|
|
1x70 |
9.4 |
1.1 |
1.0 |
1.25 |
1.8 |
19.7 |
|
|
1x95 |
11.0 |
1.1 |
1.0 |
1.6 |
1.8 |
22.0 |
|
|
1x120 |
12.4 |
1.2 |
1.0 |
1.6 |
1.8 |
23.6 |
|
|
1x150 |
13.8 |
1.4 |
1.0 |
1.6 |
1.8 |
25.4 |
|
|
1x185 |
15.3 |
1.6 |
1.0 |
1.6 |
1.8 |
27.4 |
|
|
1x240 |
17.5 |
1.7 |
1.0 |
1.6 |
1.9 |
29.9 |
|
|
1x300 |
19.5 |
1.8 |
1.0 |
2.0 |
2.0 |
33.1 |
|
|
1x400 |
22.6 |
2 |
1.2 |
2.0 |
2.2 |
37.3 |
|
|
1x500 |
25.2 |
2.2 |
1.2 |
2.0 |
2.3 |
40.5 |
|
-Two core armored cables
|
Two cores (Galvanized steel wire armoured) |
|
||||||
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
|
|
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
|
|
2x1.5 |
1.4 |
0.7 |
1.0 |
0.8 |
1.8 |
12.8 |
|
|
2x2.5 |
1.8 |
0.7 |
1.0 |
0.8 |
1.8 |
13.6 |
|
|
2x4 |
2.3 |
0.7 |
1.0 |
0.8 |
1.8 |
14.6 |
|
|
2x6 |
2.8 |
0.7 |
1.0 |
1.25 |
1.8 |
16.5 |
|
|
2x10 |
3.6 |
0.7 |
1.0 |
1.25 |
1.8 |
18.1 |
|
|
2x16 |
4.5 |
0.7 |
1.0 |
1.25 |
1.8 |
19.9 |
|
|
2x25 |
5.6 |
0.9 |
1.0 |
1.6 |
1.8 |
23.6 |
|
|
2x35 |
6.7 |
0.9 |
1.0 |
1.6 |
1.8 |
25.8 |
|
|
2x50 |
8.0 |
1 |
1.0 |
1.6 |
1.9 |
29.0 |
|
|
2x70 |
9.4 |
1.1 |
1.0 |
2.0 |
2.0 |
33.2 |
|
|
2x95 |
11.0 |
1.1 |
1.2 |
2.0 |
2.1 |
37.1 |
|
|
2x120 |
12.4 |
1.2 |
1.2 |
2.0 |
2.3 |
40.5 |
|
|
2x150 |
13.8 |
1.4 |
1.2 |
2.5 |
2.4 |
45.4 |
|
|
2x185 |
15.3 |
1.6 |
1.4 |
2.5 |
2.6 |
49.9 |
|
|
2x240 |
17.5 |
1.7 |
1.4 |
2.5 |
2.7 |
55.1 |
|
|
2x300 |
19.5 |
1.8 |
1.6 |
2.5 |
2.9 |
60.2 |
|
|
2x400 |
22.6 |
2 |
1.6 |
2.5 |
3.1 |
67.7 |
|
-Three cores armored cables
|
Three cores (Galvanized steel wire armoured) |
|
||||||
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
|
|
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
|
|
3x1.5 |
1.4 |
0.7 |
1.0 |
0.8 |
1.8 |
13.2 |
|
|
3x2.5 |
1.8 |
0.7 |
1.0 |
0.8 |
1.8 |
14.1 |
|
|
3x4 |
2.3 |
0.7 |
1.0 |
0.8 |
1.8 |
15.2 |
|
|
3x6 |
2.8 |
0.7 |
1.0 |
1.25 |
1.8 |
17.1 |
|
|
3x10 |
3.6 |
0.7 |
1.0 |
1.25 |
1.8 |
18.9 |
|
|
3x16 |
4.5 |
0.7 |
1.0 |
1.25 |
1.8 |
20.8 |
|
|
3x25 |
5.6 |
0.9 |
1.0 |
1.6 |
1.8 |
24.7 |
|
|
3x35 |
6.7 |
0.9 |
1.0 |
1.6 |
1.8 |
27.2 |
|
|
3x50 |
8.0 |
1 |
1.0 |
1.6 |
1.9 |
30.6 |
|
|
3x70 |
9.4 |
1.1 |
1.0 |
2.0 |
2.1 |
35.2 |
|
|
3x95 |
11.0 |
1.1 |
1.2 |
2.0 |
2.2 |
39.3 |
|
|
3x120 |
12.4 |
1.2 |
1.2 |
2.0 |
2.3 |
43.0 |
|
|
3x150 |
13.8 |
1.4 |
1.4 |
2.5 |
2.5 |
48.6 |
|
|
3x185 |
15.3 |
1.6 |
1.4 |
2.5 |
2.7 |
53.0 |
|
|
3x240 |
17.5 |
1.7 |
1.4 |
2.5 |
2.8 |
58.5 |
|
|
3x300 |
19.5 |
1.8 |
1.6 |
2.5 |
3.0 |
64.0 |
|
|
3x400 |
22.6 |
2 |
1.6 |
3.15 |
3.3 |
73.5 |
|
-Three cores with earth cores armored cables
|
Three cores+1 (Galvanized steel wire armoured) |
|
||||||||
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
|||
|
mm^2 |
(3) mm |
(1) mm |
(3) mm |
(1) mm |
mm |
mm |
mm |
mm |
|
|
3x 16/10 |
4.5 |
3.6 |
0.7 |
0.7 |
1 |
1.6 |
1.8 |
22.7 |
|
|
3x 25/16 |
5.6 |
4.5 |
0.9 |
0.7 |
1 |
1.6 |
1.8 |
26.5 |
|
|
3x 35/16 |
6.7 |
4.5 |
0.9 |
0.7 |
1 |
1.6 |
1.9 |
29 |
|
|
3x 50/25 |
8.0 |
5.6 |
1 |
0.9 |
1 |
1.6 |
2.1 |
33 |
|
|
3x 70/35 |
9.4 |
6.7 |
1.1 |
0.9 |
1.2 |
2 |
2.2 |
38 |
|
|
3x 95/50 |
11.0 |
8.0 |
1.1 |
1 |
1.2 |
2 |
2.3 |
42.4 |
|
|
3x120/70 |
12.4 |
9.4 |
1.2 |
1.1 |
1.2 |
2 |
2.5 |
48.0 |
|
|
3x150/70 |
13.8 |
9.4 |
1.4 |
1.1 |
1.4 |
2.5 |
2.7 |
52 |
|
|
3x185/95 |
15.3 |
11.0 |
1.6 |
1.1 |
1.4 |
2.5 |
2.8 |
57.2 |
|
|
3x240/120 |
17.5 |
12.4 |
1.7 |
1.2 |
1.6 |
2.5 |
3.1 |
64 |
|
|
3x300/150 |
19.5 |
13.8 |
1.8 |
1.4 |
1.6 |
2.5 |
3.2 |
69.8 |
|
|
3x400/185 |
22.6 |
15.3 |
2 |
1.6 |
1.6 |
3.15 |
3.6 |
78.6 |
|
-Four cores,armored cable
|
Four cores (Galvanized steel wire armoured) |
|
||||||
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
|
|
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
|
|
4x1.5 |
1.4 |
0.7 |
1.0 |
0.8 |
1.8 |
14.0 |
|
|
4x2.5 |
1.8 |
0.7 |
1.0 |
0.8 |
1.8 |
14.9 |
|
|
4x4 |
2.3 |
0.7 |
1.0 |
1.25 |
1.8 |
17.0 |
|
|
4x6 |
2.8 |
0.7 |
1.0 |
1.25 |
1.8 |
18.2 |
|
|
4x10 |
3.6 |
0.7 |
1.0 |
1.25 |
1.8 |
20.2 |
|
|
4x16 |
4.5 |
0.7 |
1.0 |
1.6 |
1.8 |
23.0 |
|
|
4x25 |
5.6 |
0.9 |
1.0 |
1.6 |
1.8 |
26.7 |
|
|
4x35 |
6.7 |
0.9 |
1.0 |
1.6 |
1.9 |
29.5 |
|
|
4x50 |
8.0 |
1 |
1.0 |
2.0 |
2.1 |
34.2 |
|
|
4x70 |
9.4 |
1.1 |
1.2 |
2.0 |
2.2 |
38.8 |
|
|
4x95 |
11.0 |
1.1 |
1.2 |
2.0 |
2.3 |
42.9 |
|
|
4x120 |
12.4 |
1.2 |
1.4 |
2.5 |
2.5 |
48.6 |
|
|
4x150 |
13.8 |
1.4 |
1.4 |
2.5 |
2.7 |
53.2 |
|
|
4x185 |
15.3 |
1.6 |
1.4 |
2.5 |
2.8 |
58.1 |
|
|
4x240 |
17.5 |
1.7 |
1.6 |
2.5 |
3.1 |
64.8 |
|
|
4x300 |
19.5 |
1.8 |
1.6 |
2.5 |
3.2 |
70.4 |
|
|
4x400 |
22.6 |
2 |
1.8 |
3.15 |
3.6 |
81.3 |
|
4.Production Progress




5.Certificates:
![]() |
![]() |
6.Packing:
-Steel wooden drum (fumigation)
Cable length in each drum: 1000m/2000m or as per actual cable length requirements.
-Drum size:
As per cable length and container size
In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
-Shipping Port:
Qingdao, or other ports as per your requireents.
-Sea freight:
FOB/C&F/CIF quotation are all available.
![]() |
![]() |
![]() |
Hot Tags: underground cables, China underground cables manufacturers, suppliers, factory, 8 pin power cable, ac 120v 60hz power cord, pretty extension cord, 15 amp extension cord, lv mv hv cables, 200 ft extension cord