Fixed Wiring Cable
video
Fixed Wiring Cable

Fixed Wiring Cable

-This product is apply for AC450/750V or below power, and household electrical appliance,Instrument and apparatus, telecommunications equipment and lighting ect. fixed installation.
 -Solid copper (or aluminum) conductor, PVC insulated single core electrical wire
 -Stranded copper conductor,  PVC insulated single core electrical wire
 -Solid copper conductor,  PVC insulated and PVC sheathed round multi-core electrical wire
 - Solid or stranded copper conductor,  PVC insulated and PVC sheathed flat electrical wire(two cores or three cores)
 - Flexible copper conductor,  PVC insulated single core electrical wire
 - Flexible copper conductor,  PVC insulated twin parallel electrical wire
 -Flexible copper conductor,  PVC insulated and PVC sheathed
Send Inquiry
Chat Now
Description

1.Cable structure

ENERGY CABLES

Building & Construction
Building Wire
Single Core, Copper

71_

72_

73_

74_


2.Application:

This product is apply for AC450/750V or below power, and household electrical appliance,Instrument and apparatus, telecommunications equipment and lighting ect. fixed installation.

STANDARD

IEC60227-3:1997

CODE DESIGNATION

60227 IEC 01 (BV, Cu/PVC)

VOLTAGE

450/750V

CONDUCTOR

Copper 1.5 - 240mm2

INSULATION

PVC/FR-PVC/LSZH

MAX. OPERATING TEMP.

70°C


3.Technical specification:

CONDUCTOR

OVERALL DIAMETER

APPROX.
MASS
kg/km

MINIMUM
INSTALLED
RADIUS
mm

mm²

No./mm

MINIMUM
mm

MAXIMUM
mm

1.5

1/1.38

0.7

2.78

21.1

18

1.5

7/0.52

0.7

2.96

21.9

18

2.5

1/1.78

0.8

3.38

32.9

20

2.5

7/0.68

0.8

3.64

34.9

20

4

1/2.25

0.8

3.85

48.0

23

4

7/0.85

0.8

4.15

49.9

23

6

1/2.76

0.8

4.36

67.9

26

6

7/1.04

0.8

4.72

70.2

26

10

1/3.56

1.0

5.56

111.4

33

10

7/1.34

1.0

6.02

114.8

33

16

7/1.68

1.0

7.04

171.1

42

25

7/2.12

1.2

8.76

268.9

53

35

7/2.50

1.2

9.90

363.1

59

50

19/1.76

1.4

11.60

488.8

70

70

19/2.12

1.4

13.40

690.1

80

95

19/2.50

1.6

15.70

954.8

94

120

37/2.00

1.6

17.20

1174.9

103

150

37/2.22

1.8

19.14

1448.7

115

185

37/2.48

2.0

21.36

1805.7

128

240

61/2.22

2.2

24.38

2373.2

146


4.Technical parameter:

CONDUCTOR

CURRENT RATING (a)

ELECTRICAL CHARACTERISTICS

Nominal
Area
mm2

FIXED WIRING

Maximum DC
Resistance
@20℃
Ω/km

Maximum AC
Resistance
@90℃
Ω/km

Equivalent
Star Reactance
(trefoil)
Ω/km

Single Phase
Voltage Drop
(trefoil) @90℃
mV/Am

Unenclosed
In Air
75_

Conduit
In Air
76_

1.5

16

17

12.1

17.3

0.157

34.7

2.5

23

24

7.41

9.45

0.143

18.9

4

31

32

4.61

5.88

0.137

11.8

6

40

41

3.08

3.93

0.128

7.87

10

54

54

1.83

2.33

0.118

4.68

16

72

70

1.15

1.47

0.111

2.95

25

97

94

0.727

0.927

0.106

1.87

35

119

112

0.524

0.668

0.101

1.35

50

146

138

0.387

0.494

0.0962

1.01

70

184

170

0.268

0.342

0.0917

0.710

95

230

212

0.193

0.247

0.0904

0.528

120

267

242

0.153

0.197

0.0870

0.431

150

308

282

0.124

0.160

0.0868

0.365

185

358

320

0.0991

0.129

0.0862

0.329

240

428

361

0.0754

0.0991

0.0847

0.283

(a) Based on 40℃ ambient air temperature.
The above information is from the following sources:
• IEC 60287 Electric cables – Calculation of the current rating (all Parts)
• IEC 60364 Electrical installations of buildings
• IEC 60228 Conductors of insulated cables
Do not put in direct contact with polystyrene, polyurethane or similar thermal insulation materials.


Hot Tags: fixed wiring cable, China fixed wiring cable manufacturers, suppliers, factory, h05v r cable, h07v-u cable, h07v-r cable, h07v-k cable, h05v-u cable, h05v-r cable

Send Inquiry

(0/10)

clearall